Sample only · Fictional matter · Abbreviated for illustration
Sample Plaintiff v. Example Residential Owner, LLC, and Example Management Co.
Property Management Systems Expert Report · Emily Goodman Shortall, CPM®, ARM®
1. Executive summary of opinions
This is a property-management systems analysis. It examines how the management
organization at the Community organized the detection, documentation, repair,
escalation and verified closure of exterior guardrail conditions — what it
assigned, what it verified and what it wrote down. It does not address whether any
individual employee behaved improperly, whether any party owed or breached a legal
duty, or what caused the guest’s fall. Those questions belong to counsel and the
trier of fact; questions of structural capacity and fastener failure belong to
qualified engineers.
The record supports a layered operational-control deficiency rather than a single
missed repair. The Community’s only scheduled inspection of exterior elements
(EX000412–EX000419) omits stair towers and guardrails entirely. Three resident
requests describing the same condition at the same location over 148 days
(EX000071, EX000088, EX000103) were each dispositioned by the same technician with the
single word “tightened,” without a parts record, a torque or fastener note,
a supervisor’s verification or a return inspection. The deferral of stair-tower
replacement in two consecutive capital plans (EX000230, EX000264) was not accompanied
by any interim inspection frequency, temporary reinforcement or written notice to
ownership of the operating consequence of waiting. Six opinions emerge from the record.
2. Qualifications
I have operated commercial and multifamily real estate for twenty-three years, hold the
CPM® and ARM® designations of the Institute of Real
Estate Management, and have held portfolio-level responsibility for more than twelve
thousand apartment units, including garden-style communities of the vintage and
construction type at issue. My curriculum vitae is attached as Exhibit A.
3. Materials reviewed
- Property Management Agreement and the annual operating and capital budgets approved thereunder (EX000001–EX000058)
- Resident portal requests, work-order histories and technician dispositions (EX000060–EX000140)
- Annual exterior inspection checklists, completed forms and photographic attachments (EX000400–EX000460)
- Capital-plan drafts, deferral memoranda and owner approval correspondence (EX000220–EX000290)
- The management organization’s written policy library (EX000500–EX000581)
- Deposition transcripts of the community manager, the maintenance supervisor and the regional manager
4. Method
I traced the reported condition through each stage of the management control cycle
— detection, documentation, interim protection, referral, assignment,
escalation and verified closure — and at each stage compared what the record
shows against the practice a reasonably prudent operator of a comparable community
would maintain. Where a document or category of document that ordinarily exists was
not produced, I identify it as absent from the materials provided to me rather than as
nonexistent. Property-maintenance codes and manufacturer guidance are referenced only
as operating context; I offer no opinion on their legal effect.
5. Opinions
Opinion 1 — The inspection program was not designed to detect this
condition. The exterior checklist in use (EX000412) enumerates roofing,
gutters, siding, parking surfaces, signage and landscape irrigation. It contains no
entry for stair towers, landings, treads or guardrails. In management practice, an
inspection program defines what will be looked at, by whom, how often and against what
criterion; a condition outside that definition is found only by accident or by
complaint. Here it was found by complaint, three times.
Opinion 2 — The disposition “tightened” records a task, not
a verified result. Each of the three work orders (EX000071, EX000088,
EX000103) was closed by the responding technician without a parts entry, a description
of the fastener condition observed, a photograph or a supervisor’s sign-off. The
maintenance supervisor testified that he “would not have gone out behind”
the technician on a routine ticket. In management practice, closure of a work order
touching a life-safety element is verified by a person other than the one who performed
the work, and that verification is recorded.
Opinion 3 — Three requests for the same condition at the same location
constituted a recurrence that the system was not built to recognize. The
work-order platform in use is capable of flagging repeat requests by unit and category;
the community manager testified that the flag was “not something we turned on.”
A prudent operator treats the second report of a previously “completed”
repair as a supervisory event, not a maintenance event, because recurrence is evidence
that the first correction did not hold.
Opinion 4 — The capital deferral was not managed as an operating
decision with operating consequences. The deferral memoranda (EX000230,
EX000264) address cost and timing. Neither identifies a compensating control — an
increased inspection frequency, a load restriction, temporary reinforcement, or resident
notice — and neither advises ownership that the stair towers would continue in
service past their planned replacement date without one. In management practice, a
decision to defer replacement of a life-safety element is paired with a decision about
how that element will be managed in the interim, and both are documented.
Opinion 5 — The absence of an exterior guardrail procedure is not
attributable to an operator lacking the capacity to write one. The same policy
library (EX000500–EX000581) contains a seven-page make-ready inspection procedure
with an assigned supervising role, business-day deadlines, a designated system of record
and mandatory photographic retention. The organization knew how to construct an
inspection control. It constructed one for the interior of a vacant apartment and not
for the exterior elements its residents and guests used every day.
Opinion 6 — The management organization possessed the organizational
means to operate an effective control and did not deploy them. A work-order
system with recurrence flagging, a supervisory chain from technician to maintenance
supervisor to community manager to regional manager, an annual inspection cycle and a
capital-planning process were all in place. The deficiency was not one of resources; it
was one of design and follow-through.
6. Matters not addressed
I offer no opinion on legal duty, breach, negligence, code compliance, the structural
or metallurgical cause of the guardrail separation, medical causation or damages. I
have not inspected the Community, and I do not opine on the physical condition of the
guardrail at any point in time; my opinions concern the management system that
surrounded it.
7. Basis and right to supplement
The opinions above are held to a reasonable degree of professional certainty within the
field of property management and rest on the materials identified in Section 3. I
reserve the right to supplement or revise them should additional records, testimony or
physical evidence be produced.
Emily Goodman Shortall, CPM®, ARM®
Sample report · not signed · fictional matter · record citations are illustrative